3D + Rigid Body Tracking (BETA)

Processing options for combined 3D and 6DOF tracking from 2D data of the cameras. For more information about how to use 3D and Rigid Body tracking, see chapter 3D and Rigid Body tracking (Beta).

3D and Rigid Body Tracking is a beta feature that is still in active development and subject to change.

The following limitations apply to the current implementation:

  • The first few frames in which a rigid body is observed are used for identification of the rigid body. For these frames, the rigid body markers will appear as unlabeled 3D trajectories, and no 6DOF data will be available.

  • 6DOF data are expressed in global coordinates, no support for alternative reference coordinate systems.

  • No support for virtual markers in rigid body definitions.

  • Filtering of 6DOF data not available.

  • No support for rigid body meshes.

  • This tracking method is not supported by the QTM Scripting Interface.

  • When using twin merging, rigid body tracking is limited to data from the twin main system when using this tracking method.

3D

The 3D tab contains the settings for 3D tracking. These settings are the same as for 3D tracking only, see chapter 3D Tracking.

Rigid Body Identification

The Rigid Body Identification tab contains the settings for rigid body identification.

Identification settings

  • Require that the whole body is visible before identifying it

    When checked, all markers of the rigid body must be visible for the initial identification of the rigid body. This is recommended for the most robust identification result.

Rigid Bodies

Buttons

  • Import Bodies...

    Press to import rigid body definitions for the new rigid body tracker from the rigid body list on the 6DOF Tracking page. In the Import Rigid Bodies dialog, select the rigid bodies that you want to import.

  • Delete

    Delete the currently selected rigid body from the Rigid bodies list.

Rigid bodies list

  • Name

    Name of the rigid body.

  • Enabled

    Check to enable tracking of the rigid body.

  • Points

    Number of points included in the rigid body definition. This value cannot be edited.

  • Max. residual

    Maximum 6DOF residual used as tolerance for initial identification of the rigid body.

  • Bone tolerance

    Maximum tolerated deviation of the distance between any pair of measured markers compared to the rigid body definition, used for initial identification of the rigid body.

Rigid Body Tracking

The Rigid Body Tracking tab contains the settings for rigid body tracking.

Termination threshold

  • Missed frames

    Criterion for the rigid body tracker to stop tracking a rigid body. If the rigid body has not received enough marker observations according to the two rules below, a frame will be counted as "missed". If the rule is 3 out of the last 5, it means that the rigid body tracking for that body will be stopped if the body is counted as "missed" in 3 out of the last 5 frames.

  • Minimum markers

    The minimum number of markers on the rigid body that must be seen [by all cameras combined] to not count the frame as "missed".

  • Minimum cameras per marker

    The minimum number of cameras that must see a specific marker for it to be counted as "seen".

Tracking

The rigid body tracker uses a Kalman filter to track rigid bodies from the 2D camera data. The tracker models the rigid body motion with angular velocity and linear acceleration. The uncertainty is represented by an elliptical Gaussian probability distribution, which determines the search area for claiming markers.

The tracker can be tuned through the following parameters.

  • Max. position uncertainty (standard deviation, mm)

    Maximum tolerance value for the uncertainty of the tracked position. The output data of the tracker is filtered when the uncertainty exceeds the tolerance. When set to 0, the filter is not applied.

  • Gating threshold (standard deviations)

    The gating threshold sets a limit for the search area of predicted marker positions, expressed as the number of standard deviations of the probability of the prediction. The typical range of values is 2–8 for smaller to larger search areas.

  • Angular acceleration standard deviation (rad/s2)

    This value is a measure of the accepted error of the predicted angular velocity of the rigid bodies. The typical range of values is 10–40, with larger values for faster rotating bodies.

  • Linear jerk standard deviation (m/s3)

    This value is a measure of the accepted error of the predicted linear acceleration of the rigid bodies. The typical range of values is 1000–12000, with larger values for faster moving bodies with sudden changes in direction.

The recommended tracking parameters for angular acceleration and linear jerk are applicable to capture rates of about 100 Hz. The uncertainty of the Kalman filter increases with decreasing sample rate and vice versa. To compensate for this, it is recommended to adapt the Angular acceleration and Linear jerk parameters as follows:

  • For low capture rates, the values should be decreased.

  • For high capture rates, the values should be increased.

Lower values of the motion parameters for angular acceleration and linear jerk put more weight on the prediction, leading to smoother movement and higher lag, whereas higher values put more weight on the measurements, resulting in lower lag but more noise.