Translating origin to the floor
For the new wand kits (carbon fiber 300 and 600, 120, active 500) the origin is automatically translated to the corner point of the L-frame at floor level.
On custom or legacy calibration kits, the origin is by default placed in the center of the corner marker on the L-frame. If you want to move the origin to another position you can use the settings on the Transformation page, see chapter Transformation. Use the following distances (in mm) if you want to translate the origin to the bottom corner of the L-frame. The distances are for the Z-axis pointing upwards, the X-axis pointing along the long arm and Y-axis pointing along the short arm.
-
Wand 750
-
x: -13.5, y: -13.5, z: -24.5
-
-
Wand 300
-
x: -8.5, y: -8.5, z: -20.5
-
-
Wand 110
-
x: -10.0, y: -10.0, z: -7.5
-
For the 300 and 750 reference, the bottom corner of the L-shape is 1 mm outside of the U-profile. The figures above are from the corner of the bottom plate, if you want the U-profile you should subtract 1 mm from x and y.